Install the gate operator only if: 

1.  The gate operator is appropriate for the construction of the gate and the usage Class of the application.  Make sure the gate is within 

the weight and length limitations specified for the operator. 

2.  All openings of a horizontal slide gate are guarded or screened from the bottom of the gate to a minimum of 4 feet (1.2m) above the 

ground to prevent a 2 1/4 inch (57.15mm) diameter sphere from passing through the openings anywhere in the gate, and in that portion 
of the adjacent fence that the gate covers in the open position. 

3.  ALL EXPOSED PINCH POINTS ARE ELIMINATED OR GUARDED AND GUARDING IS SUPPLIED FOR EXPOSED ROLLERS.  DO 

NOT INSTALL THIS DEVICE UNLESS ALL ENTRAPMENT AND PINCH POINTS ARE ELIMINATED! 

4.  The operator is intended for installation only on swing gates used to control vehicles.  Pedestrians must be provided with a separate 

access opening. 

5.  The gate must be installed in a location so that enough clearance is provided between the gate and adjacent structures when opening 

and closing to reduce the risk of entrapment.  Gates should not open into public access areas. 

6.  The gate must be properly installed and work freely in both directions prior to the installation of the gate operator.  DO NOT REDUCE 

REVERSING SENSITIVITY OR OVERTIGHTEN THE CLUTCH TO COMPENSATE FOR A DAMAGED GATE. 

7.  Gate operator controls must be placed far enough from the gate to prevent the user from coming in contact with the gate while 

operating the controls.  All activating devices must be installed in a clear line-of-sight with the gate and its travel.  Activating devices 
must be installed a minimum of 10 feet away from the gate.  Be sure to mount ALL operating devices clearly out of reach of through 
gate.  Controls intended to be used to reset an operator after two sequential activations of the entrapment protection device must be 
located in the line-of-sight of the gate.  Outdoor or easily accessible controls shall have a security feature to prevent unauthorized use. 

8.  Warning signs must be permanently installed on both sides of the gate and must be fully visible to traffic and pedestrians. 

9.  Install the gate system and gate in accordance with ASTM F220-02: Standard Specification for Automated Vehicular Gate Construction.  

For a copy of this standard, contact ASTM at (610) 832-9585, [email protected], or www.astm.org.  Install the gate system and gate in 
accordance with UL325 standards. 

Vehicular Gate Only 

Pedes

tr

ia

n

 

Access

 

Fence 

The operator is intended for installation only on swing 

gates used for vehicular traffic.  Pedestrians must be 

provided with a separate access opening. 

NO ONE SHOULD CROSS THE PATH OF A 

MOVING GATE! 

Gate operator controls must be placed far enough from 

the gate to prevent the user from coming in contact 

with the gate while operating the controls.  All 

activating devices must be installed in a clear line-of-

sight with the gate and its travel.  Be sure to mount all 

devices clearly out of reach of through gate. 

Fence 

Pilaster 

Fence 

Pilaster 

Provide spacing between the 

hinge, gate and pilaster to 

reduce the risk of entrapment for 

this area. 

Vehicular Gate Only 

Fence 

Pilaster 

Mount hinges on the 
corner of pilasters to 

help prevent 

entrapment areas. 

Building 

Or 

Structure 

Or 

Fence 

Provide spacing 

between the hinge, gate 

and building to reduce 

the risk of entrapment in 

this area 

DSW2000 Swing Gate Operator 

Summary of Contents for DSW2000

Page 1: ...nal Inc West Coast Operations 357 S Acacia Avenue 357 Fullerton CA 92831 800 221 8278 American Built www FAACUSA com Revision D FAAC International Inc Headquarter East Coast Operations 5151 Sunbeam Ro...

Page 2: ...ATOR ADJUSTMENTS Reverse Sensitivity Adjustment 14 Reverse Sensitivity Shutdown 14 Close Time Delay Adjustment 15 DIP Switch Settings 15 ACCESSORY CONNECTIONS Accessory Wire Overview 16 Edge Sensor Co...

Page 3: ...derstand the manufacturer can not be held responsible for damage or injury caused by improper erroneous or unreasonable use Failure to comply with these guidelines may create a dangerous situation and...

Page 4: ...of sight with the gate and its travel Activating devices must be installed a minimum of 10 feet away from the gate Be sure to mount ALL operating devices clearly out of reach of through gate Controls...

Page 5: ...nce some devices only cover a select area For example a photo beam will not cover the full height of a gate fence area Refer to the diagram below Contact Sensors Edge Sensors Contact sensors generally...

Page 6: ...te to align the arm with the output shaft and insert the Sheer Pin 3 Press the Release Handle down until tight 4 Attach the top arm cap cover 5 Turn power on Make sure the gate and all reversing devic...

Page 7: ...on of a wall or fence system that controls entrance and or egress by people or vehicles and completes the perimeter of a defined area VEHICULAR SWING GATE OPERATOR Or System A vehicular gate operator...

Page 8: ...fore installing the gate operator Add safety devices such as warning signs photo eyes and reverse edges to help prevent injuries or death Reduce all pinch points and protect all entrapment areas If pe...

Page 9: ...ll conduits may be located in the concrete pad terminating directly under the operator Extend each conduit a minimum of 1 above the level of the concrete pad See the Conduit Location diagram below It...

Page 10: ...HE GATE ARM To determine the arm length in a standard location 1 Make sure the Arm Operator and gate are level with each other 2 A Measure 46 from gate hinge out on gate 3 B Measure 35 5 for Long Arm...

Page 11: ...imit Cam to until it activates the top switch The switch will click when activated Tighten the Limit Cam screw if needed 4 Readjust Limits to fine tune the gate position 5 Make sure each limit cam hit...

Page 12: ...wer should be supplied from a circuit breaker panel and must have its own dedicated circuit breaker This supply must include a green ground conductor 3 Only use U L approved 14 AWG or larger 600 Volt...

Page 13: ...r DO NOT USE THESE POWER OUTLETS FOR INSTALLATION OR SERVICE TOOLS Each plug supplies 110 VAC when AC power is active to the gate operator If AC is not available the power plugs will not supply power...

Page 14: ...and the Slave operator Recommended Wire Outdoor Rated CAT 5 Cable 5 Using the supplied RS422 connectors color connect each wire MASTER ORANGE WHITE to SLAVE ORANGE WHITE Pin 1 to Pin 6 MASTER ORANGE...

Page 15: ...the gate to stop the gate while in travel The gate should stop and enter a Soft Shutdown upon striking the object 10 Repeat steps 2 6 until the correct sensitivity adjustment is found REVERSE SENSITI...

Page 16: ...the alarm in shutdown applications 2 Anti Tailgate OFF Gate opens and closes normal ON Uses loops to control vehicles individually 3 Master Slave OFF Operator is set as a Master Primary ON Operator is...

Page 17: ...TIONS ACCESSORY WIRE OVERVIEW CLOSE Photo Cell OPEN Photo Cell O P E N E D G E C L O S E E D G E Radio Receiver OPEN CLOSE STOP FIRE LOCK Card Access 1 2 3 4 5 6 7 8 9 0 Key Box 1 2 3 4 5 6 7 8 9 0 Ph...

Page 18: ...en cycle 2 An input during open cycle will stop and reverse the gate to the full closed position and enter a soft shutdown 3 NOTE If the gate was initially activated by a time clock with a contact clo...

Page 19: ...sensors shall be located where a risk of entrapment or obstruction exists such as the perimeter reachable by a moving gate or barrier and arm pinch point and entrapment areas Use caution when installi...

Page 20: ...tion to reset the operator settings Standard Reverse Input 1 Input is inactive when gate is closed or in the open cycle 2 When gate is open and Time Delay Close is ON an input will reset the Time Dela...

Page 21: ...n open position gate will remain open until an external input is made This prevents the Fire Input from closing the gate if in the open position Connecting Access Devices 1 Connect Fire Lock Control r...

Page 22: ...Radio Receivers 1 Connect Radio Relay to RADIO N O and RADIO COMMON 2 If the Radio Receiver uses 24VDC connect Radio Power to RADIO PWR 24VDC and RADIO PWR 24VDC 3 Use the following chart for standard...

Page 23: ...motion if desired 2 Allows external Warning Light to be active during gate motion Connecting External Alarm Warning Light 1 Connect Warning Light to WARNING NO and WARNING COM 2 Connect Alarm to ALARM...

Page 24: ...op slot should be 1 4 wide Cut diagonal corner slots to protect the wire insulation and keep the wire from changing directions quickly 3 Install loop wire Recommended Wire 14 AGW to 18 AGW Stranded XL...

Page 25: ...pen Loop Plug detector into left socket Make sure detector is secure and snapped in 4 Set different frequencies for each loop detector 5 Follow the directions provided with the PLD1500 for more detail...

Page 26: ...oose connection 2 Start the operator watch Sensor 1 and Sensor 2 at startup They should both blink before turning solid If only one blinks then the non blinking sensor is not being seen 3 Remove the m...

Page 27: ...s reference manuals and warning label instructions 2 Vehicular gates are for vehicles only Pedestrians must use a separate entrance Keep all pedestrian traffic away from any vehicular gate No one shou...

Reviews: