A
A
CCESSORY
CCESSORY
C
C
ONNECTIONS
ONNECTIONS
P
HOTO
S
ENSOR
C
ONNECTIONS
:
The gate operator has a Photo Close Terminal and an Photo Open Terminal for added control of the Photo Sensor functions.
The following chart describes the functions for a Photo Close Sensor and a Photo Open Sensor:
To connect a Photo Sensor:
1. Refer to the “External Entrapment Prevention” section of this manual for guidelines and placement.
2. Connect the Photo Close Sensor to PHOTO CLOSE and COMMON.
3. Connect the Photo Open Sensor to PHOTO OPEN and COMMON.
4. For Photo Sensors that use 24VDC power, connect power to +24VCD and COMMON.
Recommended Photo Sensor:
OPEN
Photo Cell
CLOSE
Photo Cell
Photo Sensor Notes:
1.
Use care to reduce the risk of
nuisance tripping, such as when a
vehicle trips the sensor while the
gate is still moving.
2.
One or more non-contact sensors
shall be located where a risk of
entrapment or obstruction exists,
such as the perimeter reachable
by a moving gate or barrier and
arm pinch point and entrapment
areas. Use caution when
installing non-contact sensors
since some devices only cover a
select area. For example, a photo
beam will not cover the full height
of a gate/fence area. Refer to the
diagrams in the “Important Safety
Information” section of this
manual.
3.
Use only UL325 compliant
devices and follow all installation
guidelines set forth by the
manufacturer.
Photo Close Input:
1. Input is only active during close cycle.
2. An input during the close cycle will stop the gate.
3. The gate will remain stopped until the input is cleared.
4. When the Photo Close is cleared, the gate will continue to
close.
Photo Open Input:
1. Input is only active during open cycle.
2. An input during open cycle will stop the gate.
3. The gate will remain stopped until the input is cleared.
4. When the Photo Open is cleared, the gate will continue to open.
DSW2000 Swing Gate Operator
19