background image

|   English

4

BSPU 800/19 - BSPU 900/24 - BSPU 1300/24

SAFETY MEASURES

Read carefully the operating instruction 

before assembling and starting. The appli-

ance must not be used by operators who 

are not thoroughly acquainted with the 

instructions handbook (operating instruc-

tions). Moreover, the appliance must not be 

used by persons under the age of 16.

 

f

The user is liable towards third parties in the area 

where the appliance is in operation.

 

f

Before  starting  it  is  necessary  to  make  sure  that 

there are the necessary electrical protection mea

-

sures, by means of a test carried out by a specialist. 

While the pump is operating persons must 

not be in the liquid to be pumped. 

The pump may be connected only by means 

of a safety switch for fault currents, with 

a rated opening current up to 30 mA and 

a socket with an earth contact installed in 

compliance with the regulations. 

Protection: at least 10 Amps. 

Operation  in  swimming  pools  and  garden 

ponds is not recommended. 

 

CAUTION: Before checking, unplug the 

pump from the mains!  

Replacing  the connecting up line requires using 

special tools and therefore this must carried out 

by the manufacturer or its service engineers. 

The pump may only operate with a pipe connect

-

ing  the  appliance  (extension)  that  is  no  lighter 

than a rubber hose mod. H07 RNF in compliance 

with the DIN 57282 or DIN 57245 standard.

 

f

The noise (continuous equivalent in dbA) of the mo

-

tor-driven pump is less or equal (≤) to 85dbA.

 

f

The  voltage  (230  Volts  alternating  current)  in

-

dicated  on  the  pump’  s  rating  plate  must  corre

-

spond to the available mains voltage.

 

f

The temperature of the liquid conveyed must not 

exceed35°C.

 

f

Make sure that the plugged electrical connections 

are in an area safe from flooding and are protect

-

ed from humidity.

 

f

Before use it is necessary to check that the plug 

and the mains connection line are not damaged.

 

f

Unplug  from  the  mains  before  performing  any 

work on the pump.

 

f

Avoid directly exposing the pump to the jet of water.

 

f

The user is responsible for complying with the lo

-

cal regulations for assembly and safety.

 

f

The user by taking appropriate measures (e.g. in

-

stalling an alarm, reserve pump and the like) will 

have to exclude the possibility of indirect damage 

caused by flooding premises due to failure of the 

pump.

 

f

In the event of the pump failing, repair work may 

only be carried out by an authorized service. Only 

genuine spare parts must be used.

ENGLISH

 

f

It  is  notified  that  in  conformity  with  the  law  on 

product liability 

 

f

We  cannot  be  held  responsible  for  the  damage 

caused by our appliance: 

1.  Because of improper repairs not carried out by 

the  personnel  of  the  assistance  points  autho

-

rized by us,

2.  If  GENUINE  SPARE  PARTS  are  not  used  to  re

-

place parts 

3.  If  the  indications  and  provisions  given  in  the 

instructions handbook are not complied with. 

The same provisions hold for the accessories.

TECHNICAL DATA

Article Number

43 487

43 488

43 489

Model

BSPU 

800/19

BSPU 

900/24

BSPU 

1300/24

Voltage / 

Frequence

V

230

230

230

Hz

50

50

50

Rated Power

W

800

900

1300

Max. height

m

38

42

50

Max.

flow rate

L/h

3500

3600

4500

Max.suction 

height

m

8

8

8

Max. Grain 

Size

mm

1

1

1

Diameter of 

Connecting 

Pipe

1”

1”

1”

Max. 

Pressure

bar

1,5~

3,0

1,5~

3,0

1,5~

3,0

Max. Noise

dB

85

85

85

Max.media 

temperature

o

C

35

35

35

Cable Lenght

m

1

1

1

Pressure 

tank volume

L

19

24

24

Weight

kg

10,4

15,0

16,5

Protection

IPX4

IPX4

IPX4

Insulation 

Class

B

B

B

USE

 

CAUTION: Sector of use  

  The pressure tanks units are used to supply

  water to houses, farms and factories when 

the  water  may  be  drawn  from  a  well  or  from  a 

spring and, in addition, for irrigation in market gar

-

dening or agriculture. To raise the pressure of the 

water  mains  in  accordance  with  local  regulations 

Summary of Contents for BSPU 800/19

Page 1: ...GINAL INSTRUCTIONS EN NOTICE ORIGINALE FR ISTRUZIONI ORIGINALI IT EL ORIGINALNO UPUTSTVO ZA RAD SR INSTRUC IUNI DE FOLOSIRE ORIGINALE RO BG ORIGINALNE UPUTE ZA RAD HR BSPU 800 19 BSPU 900 24 BSPU 1300...

Page 2: ...OOSTER PUMP UNIT 04 FR POMPE AVEC RESERVOIR DE PRESSION JET 06 IT AUTOCLAVE JET 08 EL JET 10 SR PUMPA SA REZERVOAROM POD PRITISKOM 12 HR HIDROPAK JE 14 RO HIDROFOARE JET 16 BG JET 18 TROUBLESHOOTING R...

Page 3: ...3 www ffgroup tools com BSPU 800 19 BSPU 900 24 BSPU 1300 24...

Page 4: ...dity f Before use it is necessary to check that the plug and the mains connection line are not damaged f Unplug from the mains before performing any work on the pump f Avoiddirectlyexposingthepumptoth...

Page 5: ...d and set it up for use ADJUSTING CONNECTION AND CUT OFF PRESSURE The pressure tanks unit are factory set with an operating pressure of 1 5 3 0 bar see table of specifications The connection and cut o...

Page 6: ...ues se trouvent l abri des inondations et de l humidit f Avant l utilisation v rifiez que la ligne de branche ment au r seau et la prise ne sont pas endom mag es f D branchez la prise lectrique avant...

Page 7: ...eau de la vider com pl tement et de la conserver dans un endroit sec Avant la remise en service contr lez le bon fonctionnementdelapompe Pourcefaire faites la d marrer puis arr tez la pendant quelque...

Page 8: ...f Assicurarsi che le connessioni elettriche a spina si trovino in una zona sicura da allagamenti e siano pro tette dall umidit f Prima dell uso occorre verificare che la linea di allac ciamento alla r...

Page 9: ...mpletamente e riporla in luogo asciutto Prima della rimessa in funzione controllare se la pompa funziona liberamente accendendo e speg nendo brevemente la stessa Riempire poi nuovamente la pompa con l...

Page 10: ...m DIN 57282 DIN 57245 f dbA 85dbA f 230 Volt f 35 C f f f f f f f f 1 2 3 43 487 43 488 43 489 BSPU 800 19 BSPU 900 24 BSPU 1300 24 V 230 230 230 Hz 50 50 50 W 800 900 1300 m 38 42 50 L h 3500 3600 45...

Page 11: ...11 www ffgroup tools com BSPU 800 19 BSPU 900 24 BSPU 1300 24 o C 35 35 35 m 1 1 1 L 19 24 24 kg 10 4 15 0 16 5 IPX4 IPX4 IPX4 B B B 2 bar f f 30 f 1 5 3 0 bar 1 2 2 1 2002 96...

Page 12: ...ili njegovi serviseri Pumpa mo e da radi samo sa cevi koja se povezuje sa ure ajem produ etak koja nije lak a od gumenog creva H07 RNF u skladu sa standardom DIN 57282 ili DIN 57245 f Buka trajni ekv...

Page 13: ...tite usisnu cev za povla enje vode koja nadolazi do pumpe Apsolutno izbegavajte name tanje usisne cevi na ve oj visini od pumpe formiranje vazdu nih mehuri a u usisnoj cevi f Usisne cevi i cevi za isp...

Page 14: ...dina f Korisnikjeodgovoranzatre eosobeupodru jugdje se ure aj upotrebljava f Prije pokretanja stru njak treba na propisani na in ispitati jesu li provedene sve potrebne mjere elek tri ne za tite Dok c...

Page 15: ...inom dok se ne po ne izlijevati USISNE CIJEVI f Montirajte usisnu cijev za dovod vode prema gore u smjeru crpke U svakom slu aju izbjegavajte postav ljanje usisne cijevi na polo aj vi i od crpke stvar...

Page 16: ...fa de ter e p r i n zona de punere n func iune a dispozitivului f nainte de a l porni este necesar s v asigura i c exist m suri necesare de protec ie electric prin intermediul unui test realizat de c...

Page 17: ...de aspira ie o supap de aspira ie blocare la reflux pentru a evita tim pii de aspira ie ndelunga i i deteriorarea inutil a pompei din cauza pietrelor i corpurilor str ine solide NAINTE DE PORNIRE nai...

Page 18: ...ice i electronice uzate trebuie gestionate separat i n conformita te cu regulamentele referitoare la tratarea recuperarea i reciclarea produselor men io nate mai sus n conformitate cu regulamentele ap...

Page 19: ...AL DATA 43 487 43 488 43 489 BSPU 800 19 BSPU 900 24 BSPU 1300 24 V 230 230 230 Hz 50 50 50 W 800 900 1300 m 38 42 50 L h 3500 3600 4500 m 8 8 8 mm 1 1 1 1 1 1 bar 1 5 3 0 1 5 3 0 1 5 3 0 dB 85 85 85...

Page 20: ...BSPU 800 19 BSPU 900 24 BSPU 1300 24 20 2 1 5 3 0 1 2 2 1 2002 96 EO OEEO...

Page 21: ...eign bodies Eliminate the foreign bodies Wait for the thermal cut out switch to trigger again approx 20 mins FRAN AIS R SOLUTION DES PROBL MES PROBL ME CAUSES REMEDIES Le moteur ne d marre pas Absence...

Page 22: ...ola aspirante min 30cm Versare acqua nel raccordo aspir Verificare la tenuta del tubo aspir Pulire la valvola aspirante Pulire il filtro Controllare l altezza di aspirazione Portata insufficiente Alte...

Page 23: ...umpu i zamenite dotrajale delove Prekida za za titu od pregrevanja isklju uje pumpu Preoptere enje motora Prekomerno trenje je izazvano stranim telima Elimini ite strana tela Sa ekajte da se ponovo ak...

Page 24: ...ira ie min 30 cm A se turna ap n racordul de aspira ie Se verifica etanseitatea circuitului de aspira ie A se cur a supapa de aspira ie A se cur a filtrul A se controla n l imea de aspira ie Debit ins...

Page 25: ...le disposizioni pertinenti delle Direttive e dei Regolamenti elencati di seguito nonch alle seguenti Normative AUTOCLAVE Codice prodotto EL JET SR EU IZJAVA O USAGLA ENOSTI Na sopstvenu odgovornost iz...

Page 26: ...2017 EN 55014 2 2015 EN 61000 3 2 2014 EN 61000 3 3 2013 2014 35 EU EN 60335 1 2012 A11 EN 60335 2 41 2003 A1 A2 EN 62233 2008 EN Technical file at FF GROUP TOOL INDUSTRIES 19300 Aspropyrgos Greece L...

Page 27: ...27 www ffgroup tools com BSPU 800 19 BSPU 900 24 BSPU 1300 24...

Page 28: ...www ffgroup tools com info ffgroup toolindustries com 30 210 55 98 400 19300 Athens Greece 9 5 Km Attiki Odos Aspropyrgos FF GROUP TOOL INDUSTRIES...

Reviews: