72
EZ-TEXT-M-E
Text Panel Hardware Manual
value with the panel ARROW Keys (READ/WRITE)?
h.
If you select
READ/WRITE
Access, you can enter a
Minimum
and
Maximum
Range that the operator can write to the PLC.
i.
You will notice that Password Protection is not available for the
EZSeries Set Point Display Text Panel models covered by this
manual. Password Protection is only available in the EZ-220P
model, that offers a keypad for numerical data entry.
j. You may confi gure
DATA 1
to display a decimal point that is
controlled by the PLC. The location of the decimal point must
be confi gured in your PLC ladder logic program. Place a check
mark in the box next to
PLC Controlled Decimal Point
and then
enter the
PLC Address
where the control resides. (This is DATA
1 only — you cannot confi gure PLC Control for a DATA 2 or DATA
3 embedded value.)
If PLC control for the decimal point is enabled, the program will
place a decimal point at the end of the characters representing the
data value in the Message Text fi eld —
1111.
in the fi gure above.
Then placing a value of 1–4 (BCD) or 1–5 (Decimal) in the PLC
Click on this button
to add a folder
Click on this button
to add a message
1 Enter text here
2 Click here to accept text
3 Confi gured Message will appear here
Total characters in
current message is
shown here
NOTE: Folders can
have up to 19
characters maximum.
Summary of Contents for EZ-220
Page 46: ...42 EZ TEXT M E Text Panel Hardware Manual This page intentionally left blank...
Page 65: ...61 EZ TEXT M E Text Panel Hardware Manual...
Page 80: ...76 EZ TEXT M E Text Panel Hardware Manual...
Page 81: ...77 EZ TEXT M E Text Panel Hardware Manual...
Page 88: ...84 EZ TEXT M E Text Panel Hardware Manual This page intentionally left blank...
Page 100: ...96 EZ TEXT M E Text Panel Hardware Manual This page intentionally left blank...
Page 120: ...B 14 Text Panel Hardware Manual This page intentionally left blank...
Page 150: ...I 8 EZ TEXT M Text Panel Hardware Manual This page intentionally left blank...