Cable Cubby
®
Products • Installation
2-9
Install cables in the channels as follows:
1
.
Remove a segment of a set of split AAPs by unscrewing
the nuts on the underside of the bracket that fastens the
plate to the shelf (CC 200) or shelf bracket (CC300, 600, or
800). See figure 2-4, on page 2-7.
2
.
Rest the cables in the half-moon cutouts of the split AAP
segment still mounted on the shelf (CC 200) or shelf
brackets (CC 300, 600, and 800). Place the cables so that
the connectors that require inside Cable Cubby access
protrude from the front (black side) of the split AAP
segment.
3
.
Insert the screws of the split AAP segment that you
removed in step
1
through the holes in the shelf bracket.
Ensure that the cables are free in the channels that the two
split AAP segments form without being pinched where the
two segments meet.
4
.
Secure the split AAP segment to the shelf (CC 200) or shelf
brackets (CC 300, 600, and 800) with the provided captive
washers and #4-40 nuts.
5
.
Slip the appropriate
size split grommet
over each cable with
the flange of the
grommet toward the
connector that will be accessible
inside the Cable Cubby. Snap
the grommets into the channels.
6
.
If applicable, snap the included
hole plugs into unused
channels in place of the split
grommets.
Installng the AAPs
The split AAPs can be replaced with passive Extron AAPs.
Replace a set of split AAPs as follows:
1
.
Remove the set of split AAPs to be replaced by unscrewing
the nuts on the underside the shelf (CC 200) or shelf
bracket (CC 300, 600, and 800) that fasten the plates to the
bracket (figure 2-4, on page 2-7).
2
.
Cable the rear of the AAP(s) to be installed before attaching
the AAPs to the enclosure.
3
.
Insert the screws of the AAPs through the holes in the shelf
or shelf bracket. Secure the AAPs to the shelf brackets with
the provided captive washers and #4-40 nuts.