Cable Cubby
®
Products • Maintenance and Modifications
Mantenance and Modficatons, cont’d
3-4
4
.
Cable Cubby 200
— Remove the screws at the four corners
that secure the cubby to the table (figure 3-2).
Figure 3-2 — Removing the Cable Cubby 200
5
.
Lift the enclosure from the table.
W
The flanged edges of the top of the surface enclosure
are sharp. Exercise caution when the cubby is not
installed in a table to prevent personal injury.
C
The flanged edges of the top of the cubby are
bevelled to an ultra-fine thickness of less than
0.04 (4/100)" (approximately 1 mm). These
edges are soft and can be easily nicked or bent.
Exercise caution when handling and mounting the
enclosure. Mishandling can damage the appearance
of the enclosure.
6
.
Remove the AAP shelf assembly(ies) or power module by
removing the four Phillips head screws on the front and
rear of the Cable Cubby and gently pushing the assembly
out through the bottom of the cubby.
7
Perform the desired maintenance procedure.
8
.
Carefully lower the Cable Cubby into the hole in the table.
9
.
Cable Cubby 300, 600, and 800
— From the underside of
the table, reinstall the screw clamps on the enclosure at a
height at which the clamp will reach the underside of the
tabletop.
C
Do not overtighten the Phillips head screws on
the screw clamps. Overtightening can bend the
horizontal flange of the screw clamp
im Vertrieb von
CAMBOARD Electronics
www.camboard.de
Tel. 07131 911201
Fax 07131 911203