Cable Cubby
®
Products • Maintenance and Modifications
3-5
10
.
Cable Cubby 300, 600, and 800
— Snugly tighten the
Phillips head screws on the screw clamps to secure the
enclosure to the surface.
11
.
Cable Cubby 300, 600, and 800
— Tighten the locking
thumbscrews on the screw clamps to lock the clamp in
position.
12
.
Cable Cubby 200
— Fasten the Cable Cubby 200 to the
table with the four 6-32 x 1/2" screws removed in step
4
(figure 3-2).
Replacng Cables or an AAP
Before you change the cables inside the cubby or replace one or
more AAPs on Cable Cubby 300, 600, and 800 models, you must
remove the AAP shelf assembly from the Cable Cubby. Use the
following guidelines as applicable:
1
Cable Cubby 300, 600, and 800
— If the Phillips head
screws on the front and rear of the cubby are blocked by
the table, remove the cubby from the table. See Removing
and Replacing the Cable Cubby
, steps
1
through
4
, earlier in
this chapter.
2
Cable Cubby 300, 600, and 800
— Remove the AAP shelf
assembly(s) by removing the four Phillips head screws on
the front and rear of the Cable Cubby and gently pushing
the assembly out through the bottom of the cubby.
3
Change the cables and/or AAPs the same way you
installed them. See Installing the Cables and AAPs in
chapter 2, Installation.
4
Cable Cubby 300, 600, and 800
— If you removed
the cubby from the table, reinstall the surface mount
enclosure. See Removing and Replacing the Cable Cubby,
steps
8
through
11
, earlier in this chapter.
im Vertrieb von
CAMBOARD Electronics
www.camboard.de
Tel. 07131 911201
Fax 07131 911203