CHAPTER 73
PAGE 5
MAINTENANCE MANUAL EXTRA 300SC
PAGE DATE: 12. February 2019
15
Remove rod end counter nut and throttle control cable pro-
tective swivel and wiper seal.
16
Remove clamp block (1, Figure 3) attachment bolt(s).
17
Remove clamp block from the throttle control cable.
18
Pull complete throttle control cable aft to remove from air-
craft. Secure clamp sheets.
Installation
Refer to Figure 4, Sheet 1 or 2 depending on exhaust system
installed and Figure 3.
1
Install throttle control cable according to the prior marked
routing. Ensure distance between clamp sheet at the firewall
and clamp block is 660 mm (refer to Figure 2) for standard
Gomolzig exhaust systems or 620 mm for optional Sky Dy-
namics or Chabord exhaust systems.
Front View
Clamp sheet
Throttle control cable
Firesleeve
660
mm
(62
0 m
m)
Firewall
Figure 2
Firesleeve Length
2
Renew the sealing of the firewall breakthrough at the en-
gine side of the firewall. Use firewall sealant as outlined in
Chapter 51-30-04.
3
Let the sealant slightly cure before thightening the clamp
sheet attachment bolts. This will strengthen the clamping.
4
Install clamp sheets.
Summary of Contents for 300/SC
Page 96: ...CHAPTER 28 PAGE 5 MAINTENANCEMANUAL EXTRA300 SC PAGEDATE 12 February2019 Figure 1 Fuel System...
Page 100: ...CHAPTER 28 PAGE 9 MAINTENANCEMANUAL EXTRA300 SC PAGEDATE 12 February2019 Figure 2 Storage...
Page 122: ...CHAPTER 28 PAGE 31 MAINTENANCEMANUAL EXTRA300 SC PAGEDATE 12 February2019 Figure 14 Indicating...
Page 138: ...CHAPTER 32 PAGE 12 PAGEDATE 12 February2019 MAINTENANCEMANUALEXTRA300 SC Figure 6 Brake System...
Page 228: ......
Page 229: ......