CHAPTER 28
PAGE 35
MAINTENANCE MANUAL EXTRA 300/SC
PAGE DATE: 12. February 2019
28-40-03
Tubular Tank Unit (Center Tanks)
For VDO-System:
The ground wire is connected to one attachment bolt of the
tubular tank unit .
For Datcon-System:
The ground wire is connected
to the ground stud (also refer
to Figure 15)
For Centroid Products
system:
The ground wire is con-
nected to the NEG stud.
Refer to Figure 16.
Removal/Installation
1
Drain the fuel system per
Chapter 12-10-02.
2
Loosen one bolt and replace by a M5 threaded rod (1) for
securing the slotted retainer ring (2).
3
Remove the other bolts and
the ground wire.
4
Lift tubular tank unit and sealing ring over the threaded rod.
5
Remove the threaded rod and turn out the slotted retainer
ring (2).
W A R N I N G
Stripping solvents can be toxic and volatile. Use only
in well ventilated areas. Avoid physical contact with
solvent and do not inhale vapors. Keep solvent contain-
ers covered when not in use.