5
II
IMPORTANT INFORMATION
Carefully observe the following items upon
equipment receipt:
A • Check for possible damage resulting from
transportation and, should you find any irregularities,
contact your dealer immediately.
B • The water filter, water inlet hose, plastic scoop,
warranty certificate and technical support network can be
found inside the ice storage bin. Notice that the water
inlet hose has a connection that is curved at 90°. This
connection is specific for the machine's water solenoid
valve (63).
C • In model EGC 150M, the items above are inside the
machine.
D • The parts and accessories of the ice bin are inside it.
Warning:
Only connect the equipment to the drinking
water supply.
The removable hose set provided with the
ice machine must be connected to the water
network. It is forbidden to reuse the hose or
use a hose from a washing machine.
Do not store explosive substances, such as
aerosol cans containing a flammable
propellant in this device.
This device is dedicated to domestic
use, such as:
• Kitchen areas in stores, offices and other
work environments;
• Farm houses, hotels, motels and other
types of residential environments;
• Environments like hostels;
• Caterers and other non-retail applications.
EQUIPMENT INSTALLATION
Observe the following items carefully when installing the equipment:
A • Check if the place has drinking water.
B • The equipment must be leveled.
C • Check if the fan blades (24) turn freely.
D • Make sure the voltage of the power supply network is in accordance with the one identified on the power
cord of the equipment.
For 127V from 103V to 135V
For 220V from 198V to 242V
E • The plug used allows your equipment to be grounded, thus avoiding the occurrence of electrical
discharges.
If the electrical installation (NBR14136) is not in compliance, the installation will be
carried at the user's own risk.
F • The water supply network shall be provided with a specific valve to use the machine. The diameter of the
pipes should be at least V2"(12.7mm), with maximum pressure recommended for use of 0.392 MPa
(4.0kgf/cm2) and the minimum pressure of 0.029 MPa (0.3kgf/cm2).
G • The water is removed using a flexible hose, which should be placed in the sewage entry point below the
machine level, and with the capacity of absorbing at least 3 liters per minute. In the EGC-150MA model, the
sewage entry point should be below the tank level.
This equipment is not intended for use by people - including children - with reduced physical, sensory or
mental capacity, or by people with lack of experience and knowledge, unless they have received instructions
regarding the use of the equipment or they are under the supervision of a person responsible for their safety. It
is recommended that children be supervised to ensure that they do not play with the equipment.
Summary of Contents for EGC 100 A / 150 A
Page 12: ...OVERVIEW EGC 50A COVER COOLING SYSTEM...
Page 14: ...13 I OVERVIEW EGC 150MA I...
Page 15: ...14 COOLING SYSTEM EGC 50A EGC 75A EGC 100A AND EGC 150A I COOLING SYSTEM EGC 150MA I...
Page 16: ...ELECTRICAL ELECTRONIC PART...
Page 17: ...TROUGH DISPLACEMENT SYSTEM DISPLACEMENT ARM ASSEMBLY TROUGH...
Page 36: ...35...