26
Product-manual Model: 637+/D6R KD6R
07-02-09-01-E-V0402.doc
Connector assignment and functions
Signal connections
Control signal plug X10
SUB D25 socket
Connection example
model: SUB D 25
control signal plug X10
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
drive side
spread out
spread out
PLC
+/- 10V
+24V, I/O-supply
output ready
input active
0V reference point, I/O-supply
24V
+
-
0V
mecanical
limit switches
1)
1)
~
=
L1
N
2)
~
=
L1
N
option: brake
Eurotherm
AC-Servomotor
3 ~
V1
K1
+24V (br)
0V (br)
AC-Servomotor
3 ~
X10.23
X10.9
Brake-Connection Type A
:
when Isolation-Type of Break - Installation is
Basic (not PELV). The PELC - Isolation of
Control - Cirquits is uneffected.
Brake-Connection Type B
:
when isolation-type of break - installation is
PELV.
PELV-
isolation
2)
V1: Varistor e.g.. Siemens Q69X3431, 38V DC
K1: Couple-relais min. 2A,/60VDC PELV Isolation
Supply may be used for mutliple brakes
option: brake
1) Security- and supervising logic, to be programmed by user !
2)
IMPORTANT:
The Power-Supply for the Motor-Brake has to be adapted to the type of Brake. Voltage-Drops
caused by long cables also may effect malfunctions of the Brake
Summary of Contents for 637+/D6R KD6R
Page 78: ...78 Product manual Model 637 D6R KD6R 07 02 09 01 E V0402 doc Certificates ...
Page 79: ...Product manual Model 637 D6R KD6R 07 02 09 01 E V0402 doc 79 Certificates ...
Page 80: ...80 Product manual Model 637 D6R KD6R 07 02 09 01 E V0402 doc Certificates ...
Page 81: ...Product manual Model 637 D6R KD6R 07 02 09 01 E V0402 doc 81 Certificates ...
Page 82: ...82 Product manual Model 637 D6R KD6R 07 02 09 01 E V0402 doc Certificates ...
Page 83: ...Product manual Model 637 D6R KD6R 07 02 09 01 E V0402 doc 83 Certificates ...
Page 85: ...Product manual Model 637 D6R KD6R 07 02 09 01 E V0402 doc 85 16 Notes ...