16
Before
each use
After 1st
month and
every 20
hours
Every 50
hours or
3 months
Every 100
hours or 6
months
Every 300
hours or
every year
Check the oil level
C
Change the oil
V
V
Check air filter
C
Clean air filter
R
Oil filter holder
R
Oil filter
R
Spark plug
R
Cylinder head
R
Fuel tank
R when necessary
C = check
V = replace
R = clean
B = adjust
Change the oil
Undo the dipstick and remove.
Undo the drainage plug and let the oil run out of the crank case. Make sure that all of the oil has
drained out.
Do up the drainage plug
Pour new oil into the device up to the top mark; use SAE 15-W40 oil for a 4-stroke petrol engine.
Replace dipstick and do up securely.
Clean air filter
See page 5.
Clean spark plug
Remove the spark plug cap.
Undo the spark plug using a plug spanner and remove the carbon deposits from the plug.
Measure the space between the electrodes: they should be 0.7 to 0.8 mm.
Secure the spark plug and replace the cap.
Maintaining fuel filter
Turn the fuel tap to OFF (closed) and take the fuel filter out of the tank opening.
Thoroughly clean the filter.
Secure a new rubber washer to the filter and replace carefully back into the opening.
Storage
If the generator is to be stored for a long period, you must take the following measures:
1.
Undo the fuel drainage cap and let the fuel run out of the carburettor.
2.
Undo the drainage plug and let the oil run out of the crank case.
3.
Replace the oil drainage plug.
4.
Fill the generator with oil to the upper mark on the dipstick.
5.
Pull the starter rope out until you feel resistance.