Appendix A: Model 2090 GPIB Command Reference
Model 2090 Multi-Device Controller
LIST OF MODEL 2090 GPIB COMMANDS
1050/51/53 Command Set Supported by 2090:
UP
Move Tower Boom Up
DN
Move Tower Boom Down
ST
Stop Tower Boom Motion
CP
Prepares Controller to respond to future reads with the Current Position †
UL
Prepares Controller to respond to future reads with the Upper Limit †
LL
Prepares Controller to respond to future reads with the Lower Limit †
PV
Change Boom Polarization to Vertical
PH
Change Boom Polarization to Horizontal
LD
Load either CP, UL, or LL into the controller
P?
Prepares Controller to respond to future reads with the current polarization †
1060 Command Set Supported by 2090:
CW
Move Turntable Clockwise
CC
Move Turntable Counterclockwise
ST
Stop Turntable Motion
CP
Prepares Controller to respond to future reads with the Current Position †
WL Prepares
Controller
to respond to future reads with the Clockwise Limit †
CL Prepares
Controller
to respond to future reads with the Counterclockwise limit
†
LD
Load either CP, WL, or CL into the controller
† These commands are obsolete as defined. On the models 1050 and 1060, these
commands changed the front panel to display the specified value and prepared the
controller to respond to all future reads with that value. This is not compatible
with the IEEE 488.2 standard; the program
must
send the command before each
read. For programs which will not be used with a model 1050 or 1060, use the
corresponding query commands (command followed by a question mark (?))
listed below.
1090 Command Set Supported by 2090:
Note: The 1050 and 1060 command set may be used as previously noted; the
additional functionality of these commands is noted below:
CC
Move Turntable counterclockwise
CL Set
counterclockwise
limit
CL? Query counterclockwise limit
CP
Set the current position
CP? Query the current position
CW
Move Turntable clockwise
CY
Set number of scan cycles
CY? Query number of scan cycles
DN
Move Tower boom down
LH
Set the horizontal lower limit
LH? Query the horizontal lower limit
98
© ETS-Lindgren– April, 2006
Revision G– P# 399199
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com