Model 2090 Multi-Device Controller
not offer flash upgrade support and will have to be replaced
in order to provide full flash capability. In order to
determine if a Model 2090 is flash compatible, remove the
top cover and examine the single board computer. Refer to
the illustrations on the next page to help identify which
SBC version is installed. The critical component is J2. A
flash compatible Model 2090 will have six sets of jumpers
while the older boards will only have five. Incompatible
boards may also be identified by a revision number less
than 2.2 or by a socketed processor. Newer SBCs will have
a revision number accompanied by the identifier “SBC332-
4”. These SBCs are all flash compatible, even if the
revision number is less than 2.2.
NOTE: Old revision SBCs may be able to run the V3.00
firmware, but will not be able to be flash upgraded in
circuit.
If the Model 2090 contains an incompatible SBC, contact
the ETS Sales department to purchase a new SBC, or to
have ETS perform the upgrade.
©ETS-Lindgren, April 2006
141
Revision G– P#399199
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com