Model 2090 Multi-Device Controller
MODEL 2090 PARAMETER LIST
The following table describes each parameter and the
available settings. In general, the term “tower” will be used
to refer to any linear positioning device, and the term
“turntable” will refer to any rotational positioner.
Parameter Description
P1
Refers to the principal type of device to be controlled:
0 = Turntable, Reverberation Paddle, MAPS, or other rotational
positioner.
1 = Tower or other linear positioner.
P2
Refers to model specific features of device to be controlled:
0 = Standard Turntable / Tower
1 = Air Flotation Turntable / Bore Sight Tower
2 = Two Speed Turntable
NOTE: Parameter P2 for a turntable no longer supports a setting 3 =
Variable Speed Turntable/Tuner, which was introduced in V 2.25.
Instead, the 2090 now checks what type of motor base is attached and
automatically enables variable speed if it is available.
P3
Refers to SCAN cycle count in full cycles:
1-999 = Number of complete circuits to perform from one limit
to the other and back again.
000 = Infinite scan count; scan mode does not automatically
terminate.
The Model 2090 also supports a half-cycle scan count through the
GPIB interface.
©ETS-Lindgren, April 2006
45
Revision G– P#399199
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com