![Etnyre Black-Topper Operation Maintenance Safety Download Page 17](http://html.mh-extra.com/html/etnyre/black-topper/black-topper_operation-maintenance-safety_2433785017.webp)
16
INTRODUCTION
6a
6b
6c
6d
6f 6h 6j
6e 6g 6i
6k
6l
6m
REAR TOUCH SCREEN CONTROL PANEL
1. WING FOLD Switches
Spray bars have fixed center sections and fold
-
ing wings on both sides. Spray bars that have the
corresponding One Foot switches turned ON will
increase the spray width when the wing is lowered
and decrease the spray width when raised beyond
the wing tilt switch setting.
It is always a good practice to turn OFF the corre-
sponding One Foot switches before raising the wing
while spraying.
2. EMERGENCY STOP Switch
Both the POWER switch in the cab and the EMER-
GENCY STOP switch at the rear must be ON for the
control system to be on. The entire system can be
shut down by turning either switch to OFF.
Before turning either switch ON be sure you know
what will automatically activate. The EMERGENCY
STOP switch is turned Off by pushing in,
and turned On by rotating counter clockwise.
3.) Joystick
The Joystick shifts the spray bar left and right, and
moves it up and down. If the spray bar is latched, the
spray bar cannot shift left or right.
4. Left Bar
(Variable Width Bar only)
For variable bar units, the left bar thumbwheel will
shift the left spray bar left or right at four-inch incre-
ments.
5. Right Bar
(Variable Width Bar only)
For variable bar units, the right bar thumb wheel
will shift the right spray bar left or right at four-inch
increments.
6.
TOUCH SCREEN DISPLAY
a.) Gear Icon
b.) Lights Icon
c.) English / Metric units
d.) Approximate volume of Material in Tank
(Gallons or Liters)
e.) Home Button
f.) Faults Disabled Icon
g.) Bar Latch Icon
h.) Handrails Up Icon
i.) USB Icon for Data Logging
j.) Burner Control Icon
k.) Spray Icon
l.) AUTO / MANUAL Pump Control Icon
m.) Asphalt Pump Speed (GPM or LPM)