Detection behavior when armed
:
Always trigger alarm
: Alarm
will be triggered immediately after
detection.
Allow delayed entry
: Alarm will be triggered after a predefined number
of seconds in case of detection. This is generally referred to as a grace
period. The grace period gives you time to disarm the system without
triggering an alarm after entering the home.
Allow walking through device
: Works in conjunction with another
device set to
Allow delayed entry
. For example, if a device (Device A)
set to Allow delayed entry is triggered and afterward a device (Device B)
set to Allow walking through device is also triggered, Device B will wait
until after the Device A grace period before exercising its assigned trigger
action. If the system is disarmed within the grace period, Device B will
disregard its assigned trigger action.
If Device B is triggered before Device A is triggered, Device B will perform
its assigned trigger action normally.
Detection behavior when disarmed:
Chime
: When the system is disarmed, a device set to chime produces a
doorbell-like sound when the device is triggered. When the system is
armed, the device alarm action reverts to its primary assigned action.
4.2.4
Removing an Existing Device
1.
From the Device screen, select a device in the Device list.
2.
Click
Remove
Device
3.
Confirm the action. The system no longer recognizes the device, and the
device is removed from the list.
4.2.5
Editing the Details of an Existing Device
1.
From the Device screen, select a device in the Device list.
2.
In the Device information area to the right of the list, edit the relevant
fields.
3.
Click
Save
. The device information is updated.
4.2.6
Device Status
The system informs you regarding the current status of each recognized device.
The status includes the following:
-
Low battery
: Replace the batteries in the device. This warning first appears
with approximately 2-months of power left in the device. It is advised to change
batteries as soon after the low battery icon appears.
-
Device has been tampered with
: The device is not working properly due to
an environmental change i.e., something hit the device.
A robbery or striking the device hard enough to stop it from functioning is not an
environmental event.
-
Lost of network connection
: The connection between the device and the
Control Panel was lost. This may occur when the device is out of RF wireless
range of the Control Panel, or if the batteries have been removed from the device.