Pagina
108
PROGRAMMINGS
DEFAULT:
- local access with password: password required for all relays;
- deactivation: both relays can be deactivated;
- activation: both relays can be activated;
- impulse: both relays can be activated for a pre-set amount of time;
- time-set: both relays can be activated for the amount of time specified when
requiring the service;
- relay condition at start-up: both relays are deactivated.
(relay number)
( local access)
(
switch-off)
(start-up)
( impulse)
( time-set)
(condition at start-up) (confirm)
Pick up the handset of the system administrator extension (401).
Dial the code 2880.
Select the number of the relay to be configured (1 ~ 2).
For configurations from 1 to 5 dial:
0
to DISABLE
1
to ENABLE
For configuration 6 dial:
0
for ON
1
for OFF
2
for AUTOMATIC
Wait for the confirmation tone and hang up.
ST
SERIES TELEPHONES MEMORY BUTTONS
ST series telephones (ST200, ST350, ST400 and ST500) are provided with 13
or 15 direct memory buttons, which can be used to activate Hi-Pro services.
This programming allows you to modify the factory settings, and to associate
each button with a certain Hi-Pro service.