DESCRIPTION 9
-
2 inputs for auxiliary alarm
-
Alarm from diagnostics
-
Alarm from remaining SIM credit (only with GSM200 module)
•
Automatic Test Call (EN-81:28 4.2.1).
•
12 telephone numbers that, during programming, can be individually
associated with:
-
emergency-call alarm
-
technological alarms and diagnostics
-
remaining SIM credit alarm
-
automatic test call
•
5 types of alarm destination:
-
ordinary telephone users
-
service center with Ademco contact ID protocol
-
service center with Esse-ti protocol (HeCall).
-
service center wotking under CLI mode
-
SMS (only with GSM200, except for emergency-call alarms)
In case of standard telephone users, the person who answers the calls must
enter suitable programmable codes to manage the alarm. In case of service
centers with automatic protocols and software, please refer to the
corresponding documentation. In case of SMS , a text message is sent out
to the programmed telephone number warning about the alarm event.
Each type of alarm can be associated with multiple telephone numbers
(which will be called in a sequence), also with different destination types.
•
1 filter input for an external sensor in order to avoid emergency call alarms
when the car is at the floor and all doors are open or the car is moving and
the doors will open at the next floor. The filter has no effect on buttons 2
(pit) and 3 (roof), if any.
•
60 voice messages totalling 4 minutes’ recording:
-
Customisable elevator identification message (max. 22 seconds). It
must be recorded during the first installation.
-
Courtesy message broadcast in the car after the emergency call by
the trapped person (max. 22 seconds). The device is provided with a
pre-recorded courtesy message. Alternatively, you can record your
own courtesy message.
-
Pre-recorded messages that identify the type of alarm (not
customizable).