PROGRAMMING 59
Note: if the filter is enabled and the filter input is active (doors are
open or the elevator car is moving and doors are going to
open at the next floor), the alarm does not start when pressing
the emergency call button. If any, technological alarms or the
automatic test procedure are temporarily suspended to permit
HelpyL300 to record the emergency call alarm and resumed
immediately afterwards.
Warning
The filter input must be disabled during
maintenance operations of the elevator system.
Programming the filter input as normally closed / open
It allows to program the filter input as normally open or normally closed.
(setting)
¾
Lift the handset.
¾
Press 48.
¾
Enter:
0 for normally closet contact;
1
for normally open contact.
Codes for alarms’ management
You can customize the codes used for managing the alarms differently from the
factory-default settings:
−
“ACKNOWLEDGE” CODE: by default 5
−
“HANDSFREE ACTIVATION” CODE: by default 0.
−
“END” CODE: by default 9
−
“EXCLUSION” CODE: by default 1.
WARNING
Each code must be different from all others