![Ericsson RX1290 Reference Manual Download Page 135](http://html1.mh-extra.com/html/ericsson/rx1290/rx1290_reference-manual_2423529135.webp)
Technical Specification
B.5.3.2
High Speed Data over Ethernet
This connector is located at the back of the unit using the RJ-45 Ethernet port and is
enabled through the license key (RX1290/SWO/HSETHER).
Table B.26 High Speed Data Over Ethernet Connector
Item Specification
Safety status
SELV
Connector Type
RJ-45 (100BaseT)
Connector designation
10/100BaseT
Data rates (bit/s)
5 Mbps
Standards
ETSI EN 301 192 v.1.2.1 (1999-06), Section 4
De-encapsulation type
Data-Piping (Proprietary)
B.5.4
SNMP Remote Control Connector
Table B.27 SNMP Control Connector
Item Specification
Safety status
SELV
Connector type
RJ-45 (100BaseT)
Connector designation
10/100BaseT
Standard
Ericsson SNMP Control MIB
B.5.5
Alarm Connector
Table B.28 Relay Alarm Output Specification
Item
Specification
Safety status
SELV
Connector type
9-way D-type female
Connector designation:
ALARM
Contact Configuration
SPDT (Change-over)
All volt-free contacts, fully isolated.
Contact Rating
1 A at 24 V DC
1 A at 50 V AC
Maximum Switching Current
1 A
Maximum Switching Voltage
50 Vdc / 30 V AC
EN/LZT 790 0003/2 R1A
B-21
Summary of Contents for RX1290
Page 22: ...Introduction EN LZT 790 0003 2 R1A 1 14 BLANK...
Page 42: ...Operating the Equipment Locally EN LZT 790 0003 2 R1A 3 4 BLANK...
Page 68: ...Operating the Equipment Remotely EN LZT 790 0003 2 R1A 4 2 BLANK...
Page 72: ...Operating the Equipment Remotely EN LZT 790 0003 2 R1A 4 6 BLANK...
Page 74: ...Alarms EN LZT 790 0003 2 R1A 5 2 BLANK...
Page 88: ...Preventive Maintenance and Fault finding EN LZT 790 0003 2 R1A 7 2 BLANK...
Page 142: ...Technical Specification EN LZT 790 0003 2 R1A B 28 BLANK...
Page 146: ...Menus EN LZT 790 0003 2 R1A C 4 BLANK...
Page 153: ...Menus Menus EN LZT 790 0003 2 R1A C 11 EN LZT 790 0003 2 R1A C 11...
Page 168: ...Menus EN LZT 790 0003 2 R1A C 26 BLANK...
Page 170: ...Language Abbreviations EN LZT 790 0003 2 R1A D 2 BLANK...