Technical Specification
Input Specification
Duplex mode
Data Rate
1.5 – 208 Mbps
TS
CBR MPTS/SPTS feeds
Error correction
Pro MPEG FEC
B.4.7
Frame Sync Connector
The Decoder can frame lock to an external video source. The frame information is
input as a composite synchronous signal, with or without active video. The user can
offset the sync to the video output by ±32,000 HD pixels, with a resolution of one
pixel.
It is possible to connect multiple Receivers to the same reference signal. This input
requires an external 75
Ω
termination.
Table B.18 Frame Sync Connector
Item Specification
Safety status
SELV
Connector type
BNC, Female
Connector
designation
Frame Sync
Pin:
Centre
Analogue Black and Burst Input
Shield
Ground/Chassis
B.5
Output Specifications
B.5.1
Video Outputs
B.5.1.1
Analogue HD Video
Table B.19 Analogue Video Output Connectors
Item Specification
Safety status
SELV
Connector type
15-way D-type
Connector designation
Video Out
Video standards
1080 interlaced
Video level (luminance)
700 mV
±
30 mV
EN/LZT 790 0003/2 R1A
B-17
Summary of Contents for RX1290
Page 22: ...Introduction EN LZT 790 0003 2 R1A 1 14 BLANK...
Page 42: ...Operating the Equipment Locally EN LZT 790 0003 2 R1A 3 4 BLANK...
Page 68: ...Operating the Equipment Remotely EN LZT 790 0003 2 R1A 4 2 BLANK...
Page 72: ...Operating the Equipment Remotely EN LZT 790 0003 2 R1A 4 6 BLANK...
Page 74: ...Alarms EN LZT 790 0003 2 R1A 5 2 BLANK...
Page 88: ...Preventive Maintenance and Fault finding EN LZT 790 0003 2 R1A 7 2 BLANK...
Page 142: ...Technical Specification EN LZT 790 0003 2 R1A B 28 BLANK...
Page 146: ...Menus EN LZT 790 0003 2 R1A C 4 BLANK...
Page 153: ...Menus Menus EN LZT 790 0003 2 R1A C 11 EN LZT 790 0003 2 R1A C 11...
Page 168: ...Menus EN LZT 790 0003 2 R1A C 26 BLANK...
Page 170: ...Language Abbreviations EN LZT 790 0003 2 R1A D 2 BLANK...