Open information
DESCRIPTION
48 (69)
Uppgjord (även faktaansvarig om annan) -
Prepared (also subject responsible if other)
Nr
-
No.
KL/ECS/SMK Magnus Lindahl
MRS3000 Programmers reference manual
Dokansv/Godk -
Doc respons/Approved
Kontr
-
Checked
Datum
-
Date
Rev
File
KL/ECS/S/MK
1997-04-16 A
LZB 119 1661
PROG.DOC
Table Row Data Comment
90
01
01
First route digit = 1
90
02
02
Second route digit = 2
90
03
0E
Dial first tone call digit
90
04
0E
Dial second tone call digit
90
05
0E
Dial third tone call digit
90
06
0E
Dial fourth tone call digit
90
07
0E
Dial fifth tone call digit
90 08 05 Five
digits
to
dial
TEL DIGITS 7 (AREA 2 TAB 91)
ROW 01-ROW 02:
Route.
Value
range:
00-09h
= Route digits 0 through 9
0Eh
= Reference to dialled DTMF digit
0Fh
= In both ROW 01 and ROW 02 means auto selection of route.
ROW 03-ROW 07:
Tones
to
transmit.
Value
range:
00-09h
= Tones 0 through 9 in choose tone system
0Eh
= Reference to dialled DTMF digit
ROW
08:
Number of DTMF digits to dial.
Value range: 00-07h
This TAB describes the transmitted tone call and the DTMF digits to dial when function code 7
has been dialled. The transmitted tone call will be a normal call.
Example (default) :
When function code 7 has been dialled, the five tones in the tone call shall be dialled.
The route is auto-selected.
Table Row Data Comment
91 01 0F
91 02 0F Auto-selection
of
route
91
03
0E
Dial first tone call digit
91
04
0E
Dial second tone call digit
91
05
0E
Dial third tone call digit
91
06
0E
Dial fourth tone call digit
91
07
0E
Dial fifth tone call digit
91 08 05 Five
digits
to
dial