Open information
DESCRIPTION
7 (8)
Uppgjord (även faktaansvarig om annan) -
Prepared (also subject responsible if other)
Nr
-
No.
KL/ECS/S/MK Magnus Lindahl
MRS3000 Step by step programming guide
Dokansv/Godk -
Doc respons/Approved
Kontr
-
Checked
Datum
-
Date
Rev
File
KL/ECS/S/MK
1997-04-16 A
LZB 119 1661
STEP.DOC
The following personality programming has to be done:
•
In each CU200/210 set BFS FUNCTION FLAG (AREA 1 TAB 21 ROW 06) to 1.
Area Table Row Data
1 21 06 01
•
In the CU210 that is supposed to work as BFS master CU set BFS MASTER FLAG (AREA 1 TAB 21
ROW 07) to
Area Table Row Data
1 21 07 01
•
Set the GENERAL FLAG BFS function flag in LP210 to 1 (AREA 2 TAB 01 ROW 02).
Area Table Row Data
2 01 02 01
Sets the dial tone minimums detect time according to the Finish standard, the so called Morse S dial
tone. This type of dial tone consists of three 200 ms 425 Hz bursts separated by 300 ms pauses. Setting
the minimum tone detect time to 1.1 s and the maximum pause time to 350 ms specifies it.
Area Table Row Data
2 55 01 8B
2 56 01 A3