Tone Receiver Telegram 23 has following content:
ROW 1:
0A
= STAT_1, first type of accept-code.
ROW 2:
00
= No action, no second accept-code
ROW 3:
00
= No action, no third accept-code
ROW 4:
01
= T, S or D might not precede the STAT_1
ROW 5:
00
= don't care, no second accept-code in ROW 2
ROW 6:
00
= don't care, no third accept-code in ROW 3
ROW 7:
0F
= No Bx references to any call number-table
ROW 8:
00
= Normal priority
ROW 9:
00
= First tone is not the last one
ROW 10:
02
= First tones length type 2 (10-1500 ms)
ROW 11:
0D
= First tone is tone D = Ericsson S-tone.
ROW 12:
00
= Second tone is not the last one
ROW 13:
04
= Second tones length type 4 (80-120 ms)
ROW 14:
51
= Second tone shall be saved as the first status digit.
ROW 15:
01
= Third tone is allowed to be the last one, with accept-type as specified in ROW 1.
ROW 16:
04
= Third tones length type 4 (80-120 ms)
ROW 17:
52
= Third tone shall be saved as the second status digit.
ROW 18:
03
= Don't care when ROW 20 = FF
ROW 19:
0F
= Don't care when ROW 20 = FF
ROW 20:
FF
= No more tones
ROW 21-56:
= Don't care
WAIT ACK TIME (AREA 3 TAB 79)
Value range 00-FFh, default 4.
Timebase: 1 s/10 s
Waiting time for acknowledge, after transmitted a sequence within a tone telegram, according to
the Alternative C signalling protocol.
Example:
If no acknowledge has been detected within four seconds after we transmitted a tone telegram,
the signalling is considered failed, if acknowledge is required.
Table Row Data Comment
79 01 4 4
seconds