AREA 2 of EEPROM
GENERAL FLAG (AREA 2 TAB 01)
ROW 01 :
Repeater traffic enabled as default (at start-up)
Value range: 0 - 1
0 =
Repeater traffic disabled as default
1 =
Repeater traffic enabled as default
ROW 02 :
BFS function flag (only LP210)
Value range: 0 - 1
0 =
The LP is not in use in a BFS system
1 =
The LP is in use in a BFS system
FOUR WIRE (AREA 2 TAB 02)
Value range : 0-1, Default 0.
0 =
2-wire connection to CUs
1 =
4-wire connection to CUs
NOTE:
Hardware straps must be changed according to this set-up.
See
installation
note.
Example:
2-wire connection is used.
Table Row Data Comment
02 01 00 2-wire
connection
MAX CU OT CHANNELS (AREA 2 TAB 03)
Value range: 0-F, Default 2
Defines the maximum number of channels to be scanned to stop for squelch, (Open Traffic), for
each individual CU.
Example:
Max. two open traffic channels for each CU.
Table Row Data Comment
03
01
02
Max. two open traffic channels