Open information
DESCRIPTION
18 (69)
Uppgjord (även faktaansvarig om annan) -
Prepared (also subject responsible if other)
Nr
-
No.
KL/ECS/SMK Magnus Lindahl
MRS3000 Programmers reference manual
Dokansv/Godk -
Doc respons/Approved
Kontr
-
Checked
Datum
-
Date
Rev
File
KL/ECS/S/MK
1997-04-16 A
LZB 119 1661
PROG.DOC
MAX TOT OT CHANNELS (AREA 2 TAB 04)
Value range: 0-F, Default 3
Defines the maximum of channels to be scanned to stop for squelch, (Open Traffic), for all CUs
together.
Example:
Max. three open traffic channels totally.
Table Row Data Comment
04
01
03
Max. three open traffic channels
REAL CHANNEL (AREA 2 TAB 05)
ROW 01 - ROW 99 :
Value range low nibble:
0-F, default 0
Value range high nibble:
0-9, default 0
Table converting Route numbers to repeater code + Channel, Route number is equal to ROW
number.
Low nibble defines channel number, (0 = no channel).
High nibble defines repeater-code, (0 = no repeater-code).
Example:
Route 01 shall be channel 1, no repeater start.
Route 17 shall be channel 10, repeater start 7.
Route 21 shall be channel 1, repeater start 2.
Table Row Data Comment
05
01
01
Channel 1, no repeater start
05
17
7A
Channel 10, repeater start 7
05
21
21
Channel 1, repeater start 2
RADIO (AREA 2 TAB 06)
Value range: 6-7, Default 6
Specifies which radio-interface to use:
6 =
F600
7 =
F700
(The interfaces are now identical)
Example:
Radio F600 shall be used
Table Row Data Comment
06 01 6 Radio
F600