Open information
DESCRIPTION
4 (8)
Uppgjord (även faktaansvarig om annan) -
Prepared (also subject responsible if other)
Nr
-
No.
KL/ECS/S/MK Magnus Lindahl
MRS3000 Step by step programming guide
Dokansv/Godk -
Doc respons/Approved
Kontr
-
Checked
Datum
-
Date
Rev
File
KL/ECS/S/MK
1997-04-16 A
LZB 119 1661
STEP.DOC
Route information
All route information displayed in the CUs is translated by this table between a 2-digit route (01-99) and
the used channel number 1-15, and the eventual corresponding relay start digit (1-9). This is specified in
table "REAL CHANNEL" in
MRS3000 PROGRAMMERS REFERENCE MANUAL.
Open traffic limitations
The radio might, beside the tone-scanning, stop for squelch at the channels selected by one or more
CUs. Doing this check on a bunch of channels simultaneously will probably cause a chaotic behaviour.
Therefore it is possible to limit the number of squelch checked channels within the system, as well as
number of channels for a single CU200.
See "MAX TOT OT CHANNELS" and "MAX CU OT CHANNELS" in
MRS3000 PROGRAMMERS
REFERENCE MANUAL.
Time from lost squelch at a channel until accepting squelch detect at another open traffic channel, is
specified in "OT SQ HANG TIME" in
MRS3000 PROGRAMMERS REFERENCE MANUAL
.
Specifications of different time-out values
After a connection has been established by a tone call, the time from loss of both squelch from radio
and LF-detect from the CU(s) until the LP starts to give warning tones, is specified as "LF LOST TO
WARN TIME" in
MRS3000 PROGRAMMERS REFERENCE MANUAL.
The maximum conversation time is specified as "MAX CONV TIME" in
MRS3000 PROGRAMMERS
REFERENCE MANUAL.
Max. conversation time for a repeater-call is specified as "MAX RELAY TIME" in
MRS3000
PROGRAMMERS REFERENCE MANUAL.
During squelch controlled repeater when isolated base, the hang time after loss of squelch is specified
as "SQ HANG TIME" in MRS3000 PROGRAMMERS REFERENCE MANUAL.
The maximum time a CU is allowed to continuously transmit (by PTT), is specified as "MAX TX TIME" in
MRS3000 PROGRAMMERS REFERENCE MANUAL.
The maximum time from a CU beeps for a incoming call, until it has to be answered is specified as "INC
CALL WAIT TIME" in
MRS3000 PROGRAMMERS REFERENCE MANUAL
.
The maximum time for a CU to hold the radio by the function 'Listen Channel' (by choosing a route and
pressing |Listen|), is specified as "MAX LISTEN CH TIME" in
MRS3000 PROGRAMMERS
REFERENCE MANUAL.