Open information
DESCRIPTION
16 (21)
Uppgjord (även faktaansvarig om annan) -
Prepared (also subject responsible if other)
Nr
-
No.
KL/ECS/S/MK Magnus Lindahl
MRS3000 PC programming tool
Dokansv/Godk -
Doc respons/Approved
Kontr
-
Checked
Datum
-
Date
Rev
File
KL/ECS/S/MK
1997-04-06 A
LZB 119 1661
PC.DOC
3.5
CHANGE TX TONE TABLES
If "Change TX Tone table" is selected in the main menu, the following screen will appear.
cu200.mem
Transmit tone table 1: OCALLINDb
Tone System
41
Repeater code telegram Enable
52
Prolonged tone
77
Prolonged tones length (ms) 510
Preamble length (ms)
50
Tone value 1
4C
Tone value 2
41
Tone value 3
52
Tone value 4
4D
Tone value 5
34
Tone value 6
0
Tone value 7
1
Tone value 8
1
Tone value 9
0
Tone value 10
FF
Tone value 11
B1
Save Load Previous
Next
Fill
table
table
address
F1 F2 F3
F4
F5
You will move and update entries in the exact same way as in the "Change RX tone tables" menu.
With the function keys you will be able to select between the following actions:
F1 Save
If you press the
F1
key the whole configuration will be saved on file.
F2 Load
If you press the
F2
key, you will be asked for a new configuration to be read in to memory.
F3 Previous table
If you press the
F3
key the previous TX tone-table will appear on the screen. The cursor will
reside at the corresponding entry in the new table. This is, together with the command “Next
table”, very convenient when you are changing the same entries in several tables. The current
table name is shown at the top of the screen so it will be easier to update the correct table.