WorkForce 1100/Epson Stylus Office T1110/B1100/T1100/Epson ME Office 1100
Revision C
Disassembly And Assembly
Disassembling the Printer Mechanism
91
Confidential
11. Remove the CR Drive Belt from the CR Motor Pinion Gear.
Figure 4-65. Removing the CR Drive Belt
12. Remove the four C.B.S. (P4) M3 x 6 screws that secure the CR Guide Plate, and
remove it from the Main Frame.
Figure 4-66. Removing the CR Guide Plate
13. Loosen the C.B.S. (P4) M3 x 8 screw that secures the Left Parallelism Adjust
Bushing, and rotate the Bushing toward the front of the Printer Mechanism to
prevent interference between the Flag of the Parallelism Adjust Bushing and the
Left PG Cam.
Figure 4-67. Rotating the Left Parallelism Adjust Bushing
14. Slide the Left CR Shaft Mounting Plate upwards, and release the tab on the Left
CR Shaft Mounting Plate from the notch on the Main Frame to rotate the
Mounting Plate toward you.
Figure 4-68. Rotating the Left CR Shaft Mounting Plate
Align the positioning holes on the CR Guide Plate with the
seven tabs on the Main Frame.
See Figure 4-66 (p.91)
Tighten the screws in the order shown in
Figure 4-66
.
CR Drive Belt
CR Motor Pinion Gear
4
3
2
1
8) C.B.S. (P4) M3x6
(8±1 kgf.cm)
8) C.B.S. (P4) M3x6
(8±1 kgf.cm)
CR Guide Plate
Tabs
6) C.B.S. (P4) M3x8
(5±1 kgf.cm)
Left PG Cam
Flag of the Parallelism Adjust Bushing (Left)
Left CR Shaft
Mounting Plate
Tab
Summary of Contents for WorkForce 1100
Page 8: ...Confidential C H A P T E R 1 PRODUCTDESCRIPTION ...
Page 21: ...Confidential C H A P T E R 2 OPERATINGPRINCIPLES ...
Page 29: ...Confidential C H A P T E R 3 TROUBLESHOOTING ...
Page 61: ...Confidential C H A P T E R 4 DISASSEMBLYANDASSEMBLY ...
Page 128: ...Confidential C H A P T E R 5 ADJUSTMENT ...
Page 152: ...Confidential C H A P T E R 6 MAINTENANCE ...