WorkForce 1100/Epson Stylus Office T1110/B1100/T1100/Epson ME Office 1100
Revision C
Disassembly And Assembly
Removing the Housings
72
Confidential
4.2.7 Upper Housing / Printer Cover
1.
Remove the Decoration Plate Left/Right. (p.71)
2.
Remove the Panel Unit. (p.69)
3. Remove the seven C.B.P. M3 x 10 screws that secure the Upper Housing.
4. Remove the Upper Housing while pulling out the Panel FFC through the cutout of
the Upper Housing.
Figure 4-15. Remove the Upper Housing
1) C.B.P. M3x10
(6±1 kgf.cm)
6
1) C.B.P. M3x10
(6±1 kgf.cm)
7
1) C.B.P. M3x10
(6±1 kgf.cm)
5
2
1) C.B.P. M3x10
(6±1 kgf.cm)
1
3
1) C.B.P. M3x10
(6±1 kgf.cm)
4
Upper Housing
Route the Panel FFC correctly as shown in
Figure 4-12
.
Install the Upper Housing so that the Grounding Plate properly
protrudes through the cutout of the Upper Housing.
Figure 4-16. Routing the Panel FFC
Tighten the screws in the order shown in
Figure 4-15
.
A D J U S T M E N T
R E Q U I R E D
After replacing the following parts, be sure to apply G-74 grease to the
area specified for each part.
Upper Housing:
See Figure 6-14 on page 158.
Upper Housing
Grounding Plate