WorkForce 1100/Epson Stylus Office T1110/B1100/T1100/Epson ME Office 1100
Revision C
Disassembly And Assembly
Removing the Housings
70
Confidential
2. Disengage the nine hooks on the bottom of the Panel Unit, and remove the Panel
Unit while pulling out its tab.
3. Disconnect the Panel FFC from the Panel Board connector and remove the Panel
Unit.
Figure 4-11. Removing the Panel Unit (2)
Hook
Tab
Connector
Panel FFC
Panel Unit
Be careful not to get the Panel FFC caught underneath the
hooks on the Panel Unit.
Secure the Panel FFC to the Panel Unit with a piece of double-
sided tape.
Figure 4-12. Securing the Panel FFC