WorkForce 1100/Epson Stylus Office T1110/B1100/T1100/Epson ME Office 1100
Revision C
Disassembly And Assembly
Disassembling the Printer Mechanism
88
Confidential
4.4.5 Carriage Shaft / Carriage Unit
1.
Remove the Printhead / CSIC Assy. (p.81)
2.
Remove the CR Scale. (p.79)
3.
Remove the APG Assy. (p.78)
4. Rotate the PG Cam (Right) to adjust its positions other than PG++ downside.
Figure 4-57. Adjusting the PG Cam
Attach the Label, Ink Position (parts code: 1510078) at the
position in the figure below.
Figure 4-55. Attaching the Label, Ink Position
A D J U S T M E N T
R E Q U I R E D
After replacing the Printer Mechanism, always make the required
adjustments referring to the following.
“Chapter 5
Adjustment
(p.128)
”
Label, Ink Position
25 mm
1mm ± 1mm
C H E C K
P O I N T
When only removing the Carriage Shaft, you do not need to
perform
"5.3.2 PG Adjustment (p143)"
. In that case, mark the
position of the rib on the Parallelism Adjust Bushing (Left/Right)
before removing them, and make sure to align the markings with
the ribs when installing them.
Figure 4-56. Marking Position
Parallelism Adjust Bushing (Left)
Mark the position of the rib
Parallelism Adjust Bushing (Right)
Mark the position of the rib
PG Cam (Right)
Summary of Contents for WorkForce 1100
Page 8: ...Confidential C H A P T E R 1 PRODUCTDESCRIPTION ...
Page 21: ...Confidential C H A P T E R 2 OPERATINGPRINCIPLES ...
Page 29: ...Confidential C H A P T E R 3 TROUBLESHOOTING ...
Page 61: ...Confidential C H A P T E R 4 DISASSEMBLYANDASSEMBLY ...
Page 128: ...Confidential C H A P T E R 5 ADJUSTMENT ...
Page 152: ...Confidential C H A P T E R 6 MAINTENANCE ...