At power-on
At power-on, the APG Motor
does not operate at all.
APG Motor
1. Check that the connector cable of the APG Motor is connected
to the Main Board connector CN118.
1. Connect the APG Motor connector cable to
the Main Board connector CN118.
2. Check the APG Motor connector cable for damage.
2. Replace the APG Assy with a new one.
3. Check if the APG Motor operates normally.
3. Replace the APG Assy with a new one.
At power-on, the Pump Motor
does not operate at all.
Pump Motor
1. Using a tester, check the resistance value of the Pump Motor.
Value of resistance: 10.3
± 10%
1. If the resistance value is abnormal, replace the
Ink System with a new one.
2. Check the Pump Motor connector cable for damages.
2. Replace the Ink System with a new one.
3. Check that the Pump Motor connector cable is connected to the
Main Board connector CN117.
3. Connect the Pump Motor connector cable to
the Main Board connector CN117.
4. Check the Pump Motor connector cable for damages.
4. Replace the Ink System with a new one.
Table 3-11. Troubleshooting of Fatal Error
Occurrence
Timing
Phenomenon Detail
Faulty Part/
Part Name
Check Point
Remedy
CN118
CN117
Summary of Contents for WorkForce 1100
Page 8: ...Confidential C H A P T E R 1 PRODUCTDESCRIPTION ...
Page 21: ...Confidential C H A P T E R 2 OPERATINGPRINCIPLES ...
Page 29: ...Confidential C H A P T E R 3 TROUBLESHOOTING ...
Page 61: ...Confidential C H A P T E R 4 DISASSEMBLYANDASSEMBLY ...
Page 128: ...Confidential C H A P T E R 5 ADJUSTMENT ...
Page 152: ...Confidential C H A P T E R 6 MAINTENANCE ...