9.
Rerun the BASIC program and choose “Head Angle Confirmation Pattern” again by typing
2
and
ENTER
. Then verify that the confirmation sample is correct.
10. If the sample is incorrect, repeat steps 5-9 until the upper lines in the sample are aligned with
one another and the lower lines in the sample are exactly equidistant to one another (as shown
at B in Figure 4-15).
11. When you complete this adjustment, turn off the printer.
1: Push
Carriage Unit
Color Head
2: Replace
Angular Spacer
(one side only)
Platen Gap Adjust Lever
He ad Ba se
Figure 4-17. YMC Angular Spacer Replacement