4.2.11 CR Motor removal
1.
Remove the Housing from the printer. (Refer to 4.2.1 “Housing removal”)
2.
Disconnect the CR motor connector cable from the CN14 on the Main board with
tweezers
3.
Bring down the Carriage Lock Lever toward you using tweezers to unlock the
carriage, and move the CR Unit from the home position.
4.
Loosen the CR Timing Belt by moving the Driven Pulley Holder to the right, and
remove the CR Timing Belt from the pinion of the CR Motor.
Figure 4-53. Removing the Timing Belt
5.
Remove the two screws (C.P. SCREW, 3x4, F/ZN) while holding the CR Motor,
and remove the CR Motor.
Figure 4-54. Removing the CR motor
C A U T I O N
T
When removing the timing belt, take care not to damage the CR
Scale or the PF Scale.
Driven Pulley Holder
CR Scale
PF Scale
Timing Belt
T
When installing the CR Motor, connect the CR Motor Connector
Cable to the Main Board (CN14) securely.
T
Tightening torque for screws
•
Two screws securing the CR Motor:
C.P. SCREW, 3x4, F/ZN
: 5 ~ 7kgf.cm
A D J U S T M E N T
R E Q U I R E D
T
Once the CR Motor has been removed, make the following
adjustments:
1.
Bi-D adjustment
2.
Printing on A4-size noramal paper
3.
CR variation correction
C.P. SCREW, 3x4, F/ZN
Summary of Contents for Stylus Photo 925
Page 1: ...EPSON STYLUSPHOTO925 Color Inkjet Printer SEOT02006 SERVICE MANUAL ...
Page 5: ...Revision Status Revision Date of Issue Description A June 21 2002 First release ...
Page 11: ...C H A P T E R PRODUCTDESCRIPTION ...
Page 27: ...C H A P T E R OPERATINGPRINCIPLES ...
Page 50: ...C H A P T E R TROUBLESHOOTING ...
Page 73: ...C H A P T E R DISASSEMBLYANDASSEMBLY ...
Page 118: ...C H A P T E R ADJUSTMENT ...
Page 137: ...C H A P T E R MAINTENANCE ...
Page 146: ...C H A P T E R APPENDIX ...
Page 164: ......
Page 165: ......
Page 166: ......
Page 167: ......