88
7.
Disengage the hooks which fasten the PG Lever Complement to the CR Guide
Shaft, and take out the PG Lever Complement and belleville spring.
Figure 4-24. Removing the PG Lever Complement
8.
Remove the one screw (C.B.S.-TITE (P4), 3x6, F/ZN) securing the Parallelism
Adjusting Bush to the Main Frame, and tilt the Parallelism Adjusting Bush
forward and remove it from the CR Guide Shaft.
Figure 4-25. Removing the Parallelism Adjusting Bush
9.
Shift the CR Guide Shaft to the right and remove it, together with the CR Unit,
from the Main Frame.
10. Remove the CR Guide Shaft from the CR Unit.
Hooks
PG Lever Complement
CR Guide Shaft
C.B.S.-TITE (P4), 3x6, F/ZN
Parallelism Adjusting Bush
C A U T I O N
T
Although removing the CR Guide Shaft only is possible, never
do that; be sure to remove it together with the CR Unit. If the
CR Guide Shaft only is removed, the nozzle surface of the Print
Head comes in contact with the front surface of the paper guide,
thus missing dots can be caused.
T
When installing the CR Unit on the Main Frame, make certain
that the CR Grounding Plate and CR Slider are grounded to the
specified points on the CR Unit.
Figure 4-26. CR Grounding Plate and CR Slider Mounting Positions
CR Grounding Plate
CR Slider
Summary of Contents for Stylus Photo 925
Page 1: ...EPSON STYLUSPHOTO925 Color Inkjet Printer SEOT02006 SERVICE MANUAL ...
Page 5: ...Revision Status Revision Date of Issue Description A June 21 2002 First release ...
Page 11: ...C H A P T E R PRODUCTDESCRIPTION ...
Page 27: ...C H A P T E R OPERATINGPRINCIPLES ...
Page 50: ...C H A P T E R TROUBLESHOOTING ...
Page 73: ...C H A P T E R DISASSEMBLYANDASSEMBLY ...
Page 118: ...C H A P T E R ADJUSTMENT ...
Page 137: ...C H A P T E R MAINTENANCE ...
Page 146: ...C H A P T E R APPENDIX ...
Page 164: ......
Page 165: ......
Page 166: ......
Page 167: ......