Maintenance 13. Replacing the LED Lamp
188
E2C Rev.6
Removal
(1) Remove the arm top cover.
For details on the removal method, refer to
Maintenance: 3.1 Arm Top Cover
.
(2) Cut off the wire tie binding the duct plate,
motor, and cables together.
(3) Remove the duct plate.
Duct plate
3-M5
×
15
(4) Remove the lens and lens holder.
To remove, turn them right
(5) Remove the LED from the duct plate.
To remove, hold the LED and turn the
resin-ring.
(6) Disconnect the X1 and X2 terminals from
the LED.
X1 terminal
Lens
Lens holder
LED
Resin-ring
X2 terminal
Installation
(1) Connect the X1 and X2 terminals to the
LED.
Each terminal must be connected to its
terminal number on the LED.
(2) Mount the LED on the duct plate.
To mount, hold the LED and turn the
resin-ring.
(3) Install the lens and lens holder to the LED.
Be sure to place the lens on the lens holder.
X1 terminal
Lens
Lens holder
LED
Resin-ring
X2 terminal
(4) Mount the duct plate on Arm #2.
(5) Rebind the duct plate, motor, and cables together with a wire tie.
(6) Install the arm top cover.
For details on the installation method, refer to
Maintenance: 3.1 Arm Top Cover
.