91
Chapter3 Handling
2
Make the settings for the barcode type you selected.
• Settings for PDF417
∗
Module Width:
Set module width of PDF417.
For the recommended value, see
"Recommended Module Values" on page 93.
∗
Module Height:
Specify the ratio of PDF417 module height to the module width.
For the recommended value, see
"Recommended Module Values" on page 93.
∗
Column:
Specify the number of columns of PDF417.
∗
Row:
Specify the number of rows of PDF417.
∗
Truncation Symbol:
Select the check box to create a symbol using data excluding the stop code of
PDF417.
∗
Error Correction Level
Specify an error correction level for PDF417. This allows the symbol data to be
correctly read even if a portion of the symbol is missing or damaged. The larger
the number is, the higher the possibility of data restoration gets.
• Settings for MicroPDF417
∗
Module Width:
Set module width of MicroPDF417.
For the recommended value, see
"Recommended Module Values" on page 93.
∗
Module Height:
Specify the ratio of MicroPDF417 module height to the module width.
For the recommended value, see
"Recommended Module Values" on page 93.
∗
Column:
Specify the number of columns of MicroPDF417.
∗
Row:
Specify the number of rows of MicroPDF417.
• Settings for QR code
∗
Model:
Select a QR code model.
∗
Module:
Select a width of a cell (module) of QR code.
For the recommended value, see
"Recommended Module Values" on page 93
∗
Error Correction Level:
Specify an error correction level for QR code. This allows the symbol data to be
correctly read even if a portion of the symbol is missing or damaged. The possi-
bility of data restoration gets higher in the order of L, M, Q, and H.
∗
Character Mode:
Select a mode for data to be converted into a QR code.
• Settings for Micro QR code
∗
Version:
Specify the version of Micro QR code.
∗
Module:
Select a width of a cell (module) of Micro QR code.
For the recommended value, see
"Recommended Module Values" on page 93
∗
Error Correction Level:
Specify an error correction level for Micro QR code. This allows the symbol data
to be correctly read even if a portion of the symbol is missing or damaged. The
possibility of data restoration gets higher in the order of L, M.
• Settings for MaxiCode
∗
Mode:
Select a mode of MaxiCode.
• Settings for GS1 DataBar
∗
Module:
Set module width of GS1 DataBar.
For the recommended value, see
"Recommended Module Values" on page 93
∗
Number of Characters: Specify the max width of GS1 DataBar.
Set this if you have selected GS1 DataBar Expanded Stacked.