At power-on
At power-on, the ASF unit does
not operate at all.
ASF motor
1. Check that the ASF motor connector cable is connected to CN8
on the Main board correctly.
2. Using a tester, check that the resistance of the ASF motor is
7.0
Ω ±
10%. (Across Pins 1 and 3 and across Pins 2 and 4,
respectively)
3. Check the ASF motor connector cable for damage.
1. Connect the ASF motor connector cable to
CN8 on the Main board correctly.
2. If the resistance value is abnormal, change the
ASF motor for a new one.
3. Change the ASF motor for a new one.
At power-on, the ASF unit does
not operate at all.
Extension spring
0.618
1. Check that the Extension spring 0.618 is mounted between the
DE lock lever and DE unit.
2. Check the Extension spring 0.618 for damage.
1. Install the Extension spring 0.618 between the
DE lock lever and DE unit.
2. Change the Extension spring 0.618 for a new
one.
Table 3-17. Phenomenon-Based Fatal Error Check Points
Occurrence Timing
Phenomenon Detail
Faulty Part/Part
Name
Check Point
Remedy
ASF motor
Left rear side
Extension spring 0.618
DE lock lever
Summary of Contents for 2200 - Stylus Photo Color Inkjet Printer
Page 1: ...EPSONStylusPHOTO2100 2200 Color Inkjet Printer SEIJ01 016 SERVICE MANUAL ...
Page 8: ...C H A P T E R 1 PRODUCTIONDESCRIPTION ...
Page 39: ...C H A P T E R 2 OPERATINGPRINCIPLES ...
Page 69: ...C H A P T E R 3 TROUBLESHOOTING ...
Page 115: ...C H A P T E R 4 DISASSEMBLYANDASSEMBLY ...
Page 187: ...C H A P T E R 5 ADJUSTMENT ...
Page 214: ...C H A P T E R 6 MAINTENANCE ...
Page 226: ...C H A P T E R 7 APPENDIX ...
Page 254: ......
Page 255: ......
Page 256: ......
Page 257: ......
Page 258: ......