EPSON Stylus PHOTO 2100/2200
Revision B
TROUBLESHOOTING
Error Indications and Fault Occurrence Causes
77
Maintenance Request
Off
Blink alternately 1
Blink alternately 2
This error is detected when the Waste ink counter A0
stored in the EEPROM reaches the limit (60352 points).
The error detection timing is as follows.
• At power-on
• At data transmission
• At cleaning
• At flushing
Fatal Error
Off
High speed Blink
High speed Blink
This error is detected in any of the following cases.
1. The CR unit does not operate properly due to external
force in any sequence/operation.
2. The PF motor does not rotate properly during PF
motor operation.
3. The home position cannot be detected by the ASF
sensor.
"-"
: don't care
High speed Blink
: 0.1sec on + 0.1sec off repetition
Blink
: 0.5sec on + 0.5sec off repetition
Blink alternately 1
: 0.5sec on + 0.5sec off repetition
Blink 2
: 0.2sec on + 0.2sec on + 0.2sec on 0.4sec off repetition
Blink alternately 2
: 0.5sec on + 0.5sec on repetition
Table 3-1. Error Indications and Fault Occurrence Causes
Printer Condition
Indicators
EPSON Printer Window 3
Fault Occurrence Cause
Power
Paper
Ink 1-7
Summary of Contents for 2200 - Stylus Photo Color Inkjet Printer
Page 1: ...EPSONStylusPHOTO2100 2200 Color Inkjet Printer SEIJ01 016 SERVICE MANUAL ...
Page 8: ...C H A P T E R 1 PRODUCTIONDESCRIPTION ...
Page 39: ...C H A P T E R 2 OPERATINGPRINCIPLES ...
Page 69: ...C H A P T E R 3 TROUBLESHOOTING ...
Page 115: ...C H A P T E R 4 DISASSEMBLYANDASSEMBLY ...
Page 187: ...C H A P T E R 5 ADJUSTMENT ...
Page 214: ...C H A P T E R 6 MAINTENANCE ...
Page 226: ...C H A P T E R 7 APPENDIX ...
Page 254: ......
Page 255: ......
Page 256: ......
Page 257: ......
Page 258: ......