Now remove the mirror from the assembly by sliding it out towards the back of the machine.
To clean the mirror, use a high-quality cotton swab moistened with the optics cleaner supplied in the
accessory kit. Please read the label on the bottle carefully.
After the mirror has been cleaned and is completely dry, place it back into the assembly with the mirror
angled down towards the table. Tighten the knob that secures it, and close the small door on the back
of the assembly.
If you run out of the cleaner supplied by Epilog, Reagent or laboratory grade Alcohol can be substituted.
Also, if “Golden Grain” or “Everclear” are available in your area these are also good substitutes for the
optical cleaning solution.
Note:
Never use Isopropyl Alcohol or Hardware grade Acetone, they contain impurities which
can damage the optics in your machine.
Wet the swab thoroughly with the solvent, and then blot it against a piece of cotton so that it is no longer
soaking-wet. Then daub the lens gently, rotating the swab after each daub to expose clean cotton to
the surface until the optic is free of visible contamination. At that point, prepare a fresh swab and clean
the surface with a gentle zigzag motion across it. Avoid any hard “scrubbing” of the surface, especially
while there are visible particles on it, and try not to use repetitive circular motions. When you are done,
be careful to remove any cotton threads that may have snagged on the mountings.
- 163 -
SECTION 10: SYSTEM MAINTENANCE
Summary of Contents for Fusion Pro 32
Page 2: ......
Page 6: ......
Page 14: ...Fusion Pro 48 8 SECTION 1 SAFETY ...
Page 15: ... 9 SECTION 1 SAFETY ...
Page 18: ......
Page 28: ......
Page 60: ......
Page 98: ......
Page 108: ......
Page 132: ......
Page 162: ......
Page 184: ......
Page 202: ......
Page 214: ......
Page 216: ......
Page 242: ......