Table 5-3 The parameters in charging mode
Item
Code
MIN
Default
MAX
Unit
Remark
Real-time
charging voltage
V.OUT
V
Fixed
Output current
C.OUT
0.0
20.5
20.5
A
Real-time output
power
P.OUT
W
Fixed
Real-time input
power
V.IN
V
Fixed
Generating
capacity of day
D.GE
KWH
Manual reset;
Automatic reset
(
when
the real-time is zero
hour
)
;
Power on
Real-time date
DT
Y.M.D
Real-time time
TM
H.M.S
Equalize charging
voltage
V.EC
40.0
57.6V
60.0
V
Float
charging
voltage
V.FC
40.0
54.8V
60.0
V
Equalize Duration
T.EC
30
120
180
MIN
Equalize Calendar
CT.EC
10
30
90
DAY
Device address
ID
0
2
180
Serial port baud
rate
SBR
9600
115200
115200
B
Press
↑ or ↓ button to
change the value.
Restore
factory
settings
RSET
NO
YES
Press
↑ or ↓ button to
change the value.
Failure interface The code of failure in charging mode: IOVP, ILVP,IOCP,
OOVP, OLVP, DOTP, BOVP, CFAL
The largest figure
represents the latest
failure.
The letters represent
the failure code
The failures and pressing any button of MODE OUT will stop
the output, but the current charging status will not be affected.
The Equalize Duration will be paused when working in
equalize charging mode and the Equalize Calendar without being affected
when working in float charging mode.