Chapter III TECHNICAL SPECIFICATIONS
Table 3-1 EG1200CU technical parameters
Technical Index
Parameter
Test Condition
MIN
TYP
MAX
UNIT
AC input voltage range
176
220
265
V
AC input frequency range
47.5
50
52.5
Hz
Power factor
Vin220V,Vout40V
~
60V/20A
0.97
0.98
Surge
Vin220V,Vout60V/20A
10
A
Load regulation
Vin220V,Vout48V
,
0-20A
0.5
%
Power grid regulation
Vin187
~
242V,Vout48V/20A
0.1
%
Voltage-stabilizing accuracy Vin187
~
242V
,Vout48V
0.6
%
Efficiency
Vin220V, Vout40V
~
60V/20A
89
91.4
%
Standby power
Vin220V
10
W
Setting Range
Item
Operation Tips
MIN
Default MAX
Unit
Output voltage in power
mode
Continuous-adjustable;
Accuracy is 0.1V
40
48
60
V
Equalize Voltage
Continuous-adjustable;
Accuracy is 0.1V
40
57.6
60
V
Float Voltage
Continuous-adjustable;
Accuracy is 0.1V
40
54.8
60
V
Output current
(limitary-current)
Continuous-adjustable;
Accuracy is 0.1A
20.5
20.5
A
Equalize Duration
Continuous-adjustable;
Accuracy is one minute
30
120
180
MIN
Equalize Calendar
Continuous-adjustable;
Accuracy is one day
10
30
90
DAY
Environment Pointer
Item
Condition
MIN
TYP
MAX
Unit
Working humidity
Non-condensing
95
%
Working temperature
Output without derating at +55
℃
-15
+55
℃
Storage temperature
-40
+85
℃
Safety Index
Dielectric strength
AC-GND AC1500V one Minute
15
mA
DC-GND AC500V one Minute
0.1
mA
AC-DC AC3000V one Minute
1
mA
Structure Parameters