been finished in order to prevent the device to working in equalize
charging mode for a long time during
convert the mode repeatedly
between forced float charging mode and forced equalize charging mode.
Attention
:
“
——”means auto process; “-----” means manual process.
Figure 4-1 Charging Schematic Diagram
Section III Multi-machine Operation
Parallel Running
Multiple same type power supplies can be connected in parallel, but the
output voltage must be set at the same value. Turn on the power supply one
by one. The load voltage is the same with each power supply and the load
current is the sum of each power supply. The wiring diagram is shown
below.
Auto
Float
Equalize duration time accomplished
Power On
Factory
Reset
Auto
Equalize
Manual
Float
Manual
Equalize
Equalize interval time accomplished
By pressing “MEC” button
By pressing “MFC” button
By pressing
“MFC” button
Equalize duration
time accomplished
By pressing
“MEC” button
-10-
Summary of Contents for EG1200CU
Page 1: ...user manual Digital AC DC Power Supply EG1200CU 40 60V 0 20A USER MANUAL...