Table 6-1 The state table of protection
Item
Operation
Value
Delay
Time
(S)
Recovery
Values
ALARM
Indicator
Light
LED
Indication
Buzzer
Input overvoltage
protection
265±3V
2
250±3V
Red LED
fast blink
IOVP
Intermittent
buzzing
Input
undervoltage
protection
176±3V
2
190±3V
Red LED
slow blink
ILVP
Intermittent
buzzing
Input overcurrent
protection
12.5A
Off
IOCP
Buzzing
Output
overvoltage
protection
94V
Green
LED fast
blink
OOVP
Buzzing
Output
undervoltage
protection
30V
2
Self-recov
ery
Green
LED slow
blink
OLVP
Buzzing
Output short
circuit protection
1
Self-recov
ery
Orange
LED blink
OSCP
Buzzing
Over temperature
protection
95
℃
5
75
℃
Orange
LED slow
blink
DOTP
Intermittent
buzzing
Bus overvoltage
protection
475V
1
OFF
BOVP
Buzzing
No-load
protection in
Power Mode
0A
2
Red LED
blink
ONLP
Buzzing
Communication
failure
Orange
LED fast
blink
CFAL
Intermittent
buzzing
The null items of "Recovery Value" which need to reapply in
the table can’t be recovered automatically.
The green "ALARM " LED will be lighted on solid when
there is no failure.
Pressing any button once can stop the beep of fault alarm then
the button will recover the original function.