32
Installation Instructions - InfraStyle / InfraStyle i
Installation
EN
Installing the relay box
1
Drill one (1) hole above and two (2) holes below.
2
Insert the anchors as needed and screw in the top screw.
Allow the screw to protrude approx. 3 mm so you can hook in the
relay box.
3
Route the connection cables through the openings.
Either from below or from the rear.
Horizontal distance between drill holes: 210 mm
Vertical distance between drill holes: 180 mm
A
Lines with mains voltage, e.g.
mains supply line, heat
B
Lines with low voltage, e.g. sensor
line, S-Bus (sauna bus)
210
180
3
A
B