Installation Instructions - InfraStyle / InfraStyle i
Installation
EN
5.2.1 Terminals
Multiple IR emitters can be connected to terminals IR-1, IR-2 and IR-3. The
IR emitter lines must all have the same cross-section.
The terminal for lighting may be assigned only one line. It must only be
used for cabin lighting.
Use a plug-in module if you connect multiple emitters to one terminal.
See 5.5 Connecting and configuring consumers,
5.2.2 Emitter type – jumper JP1 and JP2
JP1 and JP2 are used to configure the emitter type for connections IR-1 and
IR-2.
R: IR emitter (R).
F: IR foil (F).
Connection IR-3 is configured for emitters at the factory.
Connections IR-1 and IR-2 are switched off if no jumper is set. IR-3 remains
switched on.
Emitters (R) are connected to IR-1 and IR-2.
Foils (F) are connected to IR-1 and IR-2.
Emitters (R) are connected to IR-1; foils (F) are connected to IR-2.
Emitters (R) are connected to IR-1.
IR-2 is switched off.