60
Installation Instructions - InfraStyle / InfraStyle i
Installation
EN
5.5 Connecting and configuring consumers
DANGER
Risk of electric shock
A faulty electrical connection poses the risk of an electric shock.
This risk also applies following completion of the installation work.
Disconnect the system entirely from the mains supply.
If retrofitting is required, the housing must only be opened by
trained personnel.
Electrical installation must only be carried out by a qualified and
licensed electrician.
The unit must be connected to the power supply according to
the circuit diagram and the terminal scheme.
Recommended sequence:
Connect IR emitter
Set jumper
Connect cabin lighting
The lines from the individual components to the relay box may not exceed
5.5 m in length. The lines must be connected as shown in the circuit dia-
gram.
You can connect multiple IR emitters to each of the terminals IR-1, IR-2 and
IR-3. The IR emitter lines must all have the same cross-section.