34
Installation Instructions - InfraStyle / InfraStyle i
Installation
EN
4.4 Control panels
The housing for the InfraStyle control panel is available in two models: for
mounting in the wall or for mounting on the wall. Both models are
designed for a mounting location on the outer wall of the cabin.
If empty conduits for electrical installations are already present, this dic-
tates the position of the control panel.
4.4.1 Guidelines
The cabin wall must be designed in such a way that the temperature in the
area in which cables are routed cannot exceed 75°C.
Line routing for InfraStyle
Guide for data and control line(s)
The following guidelines apply depending on the cabin wall:
Mounting in the wall – insulation: The control line must only be routed
between the insulation and the outer wall of the cabin.
Mounting in the wall – wooden planks: The control line is routed
between the inner wall and outer wall of the cabin.
Mounting on the wall – wooden planks: The control line is routed along
the outer wall of the cabin.
A
Inner wall of the cabin
B
Insulation
C
Control line
D
Outer wall of the cabin
C
A
B
D
C
A
D
Mounting in the wall
for cabin walls with
insulation
Mounting in the wall
for cabin walls made of
wooden planks
Mounting on the wall
for cabin walls made of
wooden planks
D
A
C